DONGHEE-KAUTEX PLASTIC INJECTION PLANT PHASE I & II
Client
Donghee
Year
PHASE I: JUN 2013 - DEC 2013 / PHASE II: APR 2015 - SEP 2015
Location
AUBURN, AL
Linked white arrow
DONGHEE-KAUTEX PLASTIC INJECTION PLANT PHASE I & II
SYSCON understands what it takes to see a major construction project to completion. One of the most vital aspects of any successful project is expert planning and preconstruction. SYSCON understands what it takes to see a major construction project to completion. One of the most vital aspects of any successful project is expert planning and preconstruction. SYSCON understands what it takes to see a major construction project to completion. One of the most vital aspects of any successful project is expert planning and preconstruction.
Project Scope Details
DESIGN
DESIGN-BUILD/ ARCHIPLAN, LLC
GENERAL CONTRACTOR
SYSCON, LLC
MAIN SUBCONRTRACTOR
LOT AREA
PHASE I: 20 ACRES / PHASE II: 7.5 ACRES
CONSTRUCTION AREA

PHASE I: 115,342 SQ FT

PHASE II: 94,500 SQ FT

Floors

PHASE I: MAIN PLANT: 75 FT HIGH / MAIN OFFICE: 20 FT HIGH

PHASE II: MAIN PLANT: 34 FT HIGHT

BUILDING STRUCTURES

S/STRUCTURESWALL

METAL PANEL (2’’)

TPO (3’’) ROOFING

FM CODE APPLIED

MAJOR ACTIVITIES

PHASE I: S/STRUCTURES: 570 TONS + CONCRETE: 3,420 CYD

PHASE II: S/STRUCTURES: 450 TONS + CONCRETE: 2,500 CYD

Project Scope Details
DESIGN
DESIGN-BUILD/ ARCHIPLAN, LLC
GENERAL CONTRACTOR
SYSCON, LLC
MAIN SUBCONTRACTOR
LOT AREA
PHASE I: 20 ACRES / PHASE II: 7.5 ACRES
CONSTRUCTION AREA

PHASE I: 115,342 SQ FT

PHASE II: 94,500 SQ FT

Project Scope Details
LOT AREA
This is some text inside of a div block.
CONSTRUCTION AREA
This is some text inside of a div block.
ELEVATION
This is some text inside of a div block.
BUILDING STRUCTURES
This is some text inside of a div block.
MAJOR ACTIVITES
This is some text inside of a div block.
DESIGN
This is some text inside of a div block.
Floors

PHASE I: MAIN PLANT: 75 FT HIGH / MAIN OFFICE: 20 FT HIGH

PHASE II: MAIN PLANT: 34 FT HIGHT

BUILDING STRUCTURES

S/STRUCTURESWALL

METAL PANEL (2’’)

TPO (3’’) ROOFING

FM CODE APPLIED

MAJOR ACTIVITES

PHASE I: S/STRUCTURES: 570 TONS + CONCRETE: 3,420 CYD

PHASE II: S/STRUCTURES: 450 TONS + CONCRETE: 2,500 CYD

Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
Project Image
No items found.
Explore our Services
Linked white arrow
Upper arrow
Syscon Icon
Syscon Icon